![]() Vogelsang offers tools that make service and repairs easier. 2,000 operating hours: Check belt tension (for pumps with belt drive) according to specification, change the quench liquid/buffer fluid, and change the gear oil.ģ) Make things easier with custom tools.500 operating hours/minimum of three months: Check the gear oil.200 operating hours: Check quench liquid/buffer fluid.20 operating hours: Tighten the screws to the motor unit, check quench liquid/buffer fluid, and change the gear oil.10 operating hours: Check belt tension (for pumps with a belt drive) according to specifications.Startup: The pump needs to be rotated (at least one revolution), and nipples need to be greased.Vogelsang has five simple but vital tips to maximize your pump’s life and ensure it’s always in tip-top shape and working efficiently.ġ) Stay on the Vogelsang recommended maintenance schedule. Keeping your rotary lobe pump in top running shape for a long life is equally, if not more, important. Get Headworks articles, news and videos right in your inbox! Sign up now.Ĭhoosing the right rotary lobe pump for your job is important.